Siemens Spare Parts
« Previous 1 … 10 11 12 13 14 … 282 Next »
6SE0143-1KC21-8AA5
DYNAVERT T 2X3A-85690-015 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 15KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC22-5AA5
DYNAVERT T 2X3A-85690-022 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 22KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC23-4AA5
DYNAVERT T 2X3A-85690-030 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 30KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC24-2AA5
DYNAVERT T 2X3A-85690-037 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 37KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC25-0AA5
DYNAVERT T 2X3A-85690-045 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 45KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC25-8AA5
DYNAVERT T 2X3A-85690-055 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 55KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC28-0AA5
DYNAVERT T 2X3A-85690-075 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 75KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC31-0AA5
DYNAVERT T 2X3A-85690-090 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 90KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC31-2AA5
DYNAVERT T 2X3A-85690-110 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 110KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC31-4AA5
DYNAVERT T 2X3A-85690-132 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 132KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC31-7AA5
DYNAVERT T 2X3A-85690-160 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 160KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0143-1KC32-1AA5
DYNAVERT T 2X3A-85690-200 400-690V IT,OPT.TN/TT, 50/60HZ TYP.MOTOR POWER 200KW (690V) ONE INVERTER MOUNTED TO CABINET HWD=2000*606*605 MM, IP21, AIR- COOLED, 6/6 PULSE SYSTEM EMV DIRECTIVE EN60204-1 INPUT CHOKE/ DU/DT OUT FILTER
6SE0170-1BA33-7AA7
SINAMICS G180 2T6A-77401-200 230-415V TN/TT, 50/60HZ TYP.MOTORPOWER 200KW (400V) HWD W/O OPT. 2002*806*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
6SE0170-1BA34-6AA7
SINAMICS G180 2T6A-77401-250 230-415V TN/TT, 50/60HZ TYP.MOTORPOWER 250KW (400V) HWD W/O OPT. 2002*806*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
6SE0170-1BA36-3AA7
SINAMICS G180 2T6A-77401-315 230-415V TN/TT, 50/60HZ TYP.MOTORPOWER 315KW (400V) HWD W/O OPT. 2002*806*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
6SE0170-1BA37-3AA7
SINAMICS G180 2T6A-77401-400 230-415V TN/TT, 50/60HZ TYP.MOTORPOWER 400KW (400V) HWD W/O OPT. 2202*1406*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
6SE0170-1BA38-8AA7
SINAMICS G180 2T6A-77401-500 230-415V TN/TT, 50/60HZ TYP.MOTORPOWER 500KW (400V) HWD W/O OPT. 2202*1806*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
6SE0170-1BA41-0AA7
SINAMICS G180 2T6A-77401-560 230-415V TN/TT, 50/60HZ TYP.MOTORPOWER 560KW (400V) HWD W/O OPT. 2202*1806*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
6SE0170-1BA41-1AA7
SINAMICS G180 2T6A-77401-630 230-415V TN/TT, 50/60HZ TYP.MOTORPOWER 630KW (400V) HWD W/O OPT. 2202*1806*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
6SE0170-1BC33-7AA7
SINAMICS G180 2T6A-77501-250 230-500V TN/TT, 50/60 HZ TYP.MOTORPOWER 250KW (500V) HWD W/O OPT. 2002*806*605MM IP54 WATERCOOLED, 6PULSE MAINS LINE CHOKE, DV/DT FILTER EMC EN61800-3 FILTEREN55011 CLASS A, SECOND ENVIRONMENT C3
We deliver worldwide and at any time including customs clearance.
In advance, we also are gladly available during an individual phone consultation.
Payment
on invoice
Worldwide
Shipping
Offers within
12 hours
Fast
delivery