Siemens Spare Parts
« Previous 1 … 174 175 176 177 178 … 30,420 Next »
1FN6007-1LE20-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N; FN,TH = 196…477N; FN = 265N; VMAX_FN = 265M/MIN; VMAX_FMAX = 120M/MIN; IN,TH = 1,69…4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,29KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LE53-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N; FN,TH = 196…477N; FN = 265N; VMAX_FN = 668M/MIN; VMAX_FMAX = 315M/MIN; IN,TH = 4,11…11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,08KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LG12-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N; FN,TH = 294…716N; FN = 398N; VMAX_FN = 169M/MIN; VMAX_FMAX = 71,7M/MIN; IN,TH = 1,69…11,2A; IN = 2,31A;IMAX =7,45A; P_N = 1,3KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LG33-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N; FN,TH = 294…716N; FN = 397N; VMAX_FN = 435M/MIN; VMAX_FMAX = 200M/MIN; IN,TH = 4,11…11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,07KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LJ08-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N; FN,TH = 392…955N; FN = 531N; VMAX_FN = 122M/MIN; VMAX_FMAX = 47,4M/MIN; IN,TH = 1,69…4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,32KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LJ24-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N; FN,TH = 392 …955N; FN = 531N; VMAX_FMAX = 320M/MIN; VMAX_FMAX = 143M/MIN; IN,TH = 4,11…11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,08KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LL05-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N; FN,TH = 490…1190N; FN = 663N; VMAX_FN = 93,9M/MIN; VMAX_FMAX = 32,4M/MIN; IN,TH = 1,69…4,6A; IN = 2,31A;IMAX =7,45A; P_N = 1,33KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LL18-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1570N; FN,TH = 490…1190N; FN = 663N; VMAX_FN = 251M/MIN; VMAX_FMAX = 110M/MIN; IN,TH = 4,11…11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,1KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LN15-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N; FN,TH = 588…1430N; FN = 794N; VMAX_FN = 206M/MIN; VMAX_FMAX = 87,9M/MIN; IN,TH = 4,11…11,2A; IN = 5,63A;IMAX =18,2A; P_N = 3,11KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1LN32-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; SELF COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1890N; FN,TH = 588…1430N; FN = 796N; VMAX_FN = 429M/MIN; VMAX_FMAX = 194M/MIN; IN,TH = 8,22…21A; IN = 11,3A;IMAX =36,3A; P_N = 6,08KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1SC00-0AA0
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; COMPENSATING PIECE OF LENGTH; FRAME SIZE 1FN6007; LENGTH 200MM
1FN6007-1SF00-0AA0
SIMOTICS L SECONDARY SECTION FOR LINEAR MOTOR 1FN6; COMPONENT 3-PHASE SYNCHRONOUS MOTOR; FRAME SIZE 1FN6007;
1FN6007-1WC31-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 315N;FN = 239N; VMAX_FN = 272M/MIN; VMAX_FMAX = 187M/MIN; IN = 3,2A;IMAX = 5,18A; P_N =1,31KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1WC46-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 315N;FN = 239N; VMAX_FN = 399M/MIN; VMAX_FMAX = 276M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =1,82KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1WE20-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N;FN = 477N; VMAX_FN = 180M/MIN; VMAX_FMAX = 120M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =1,9KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1WE53-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 630N;FN = 477N; VMAX_FN = 462M/MIN; VMAX_FMAX = 315M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,19KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1WG12-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N;FN = 716N; VMAX_FN = 111M/MIN; VMAX_FMAX = 71,7M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =2,03KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1WG33-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 945N;FN = 716N; VMAX_FN = 296M/MIN; VMAX_FMAX = 200M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,29KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1WJ08-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N;FN = 955N; VMAX_FN = 77,6M/MIN; VMAX_FMAX = 47,4M/MIN; IN = 4,6A;IMAX = 7,45A; P_N =2,17KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
1FN6007-1WJ24-0KA1
SIMOTICS L PRIMARY SECTION FOR LINEAR MOTOR 1FN6; 3-PHASE SYNCHRONOUS MOTOR; WATER COOLING SYSTEM; TWO CONNECTING BOXES FOR POWER AND SIGNAL CABLE; FMAX = 1260N;FN = 955N; VMAX_FN = 215M/MIN; VMAX_FMAX = 143M/MIN; IN = 11,2A;IMAX = 18,2A; P_N =4,43KW; PLEASE TAKE NOTE OF NATIONAL AND INTERNATIONAL LICENSE TERMS WHEN OPERATING DIRECT MOTORS SO THAT NO PATENT RIGTHS ARE VIOLATED.
We deliver worldwide and at any time including customs clearance.
In advance, we also are gladly available during an individual phone consultation.
Payment
on invoice
Worldwide
Shipping
Offers within
12 hours
Fast
delivery