4EM4912-2CB

1PH-COMMUTATING REACTOR 18A FOR 230V 50HZ VOLTAGE DROP 8.8V

4EM4912-2CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):230; ITHMAX 1(A) / F1(HZ):18 /50; I LN (A):16,2; UK(%):4; LN(MH):1,56; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >CHOKE<

4EM4912-3CB

1PH-COMMUTATING REACTOR 20A FOR 230V 50HZ VOLTAGE DROP 8.8V

4EM4912-3CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):230; ITHMAX 1(A) / F1(HZ):20 /50; I LN (A):18; UK(%):4; LN(MH):1,4; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >CHOKE<

4EM4912-4CB

1PH-COMMUTATING REACTOR 22,4A FOR 230V 50HZ VOLTAGE DROP 8.8V

4EM4912-4CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):230; ITHMAX 1(A) / F1(HZ):22,4 /50; I LN (A):20,16; UK(%):4; LN(MH):1,24; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; EN 61558-2-20 >CHOKE<

4EM4912-5CB

1PH-COMMUTATING REACTOR 25A FOR 230V 50HZ VOLTAGE DROP 8.8V

4EM4912-5CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):230; ITHMAX 1(A) / F1(HZ):25 /50; I LN (A):22,5; UK(%):4; LN(MH):1,12; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; EN 61558-2-20 >CHOKE<

4EM4912-6CB

1PH-COMMUTATING REACTOR 35,5A FOR 230V 50HZ VOLTAGE DROP 4.4V

4EM4912-6CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):230; ITHMAX 1(A) / F1(HZ):35,5 /50; I LN (A):31,95; UK(%):2; LN(MH):0,395; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; EN 61558-2-20 >CHOKE<

4EM4912-7CB

1PH-COMMUTATING REACTOR 40A FOR 230V 50HZ VOLTAGE DROP 4.4V

4EM4912-7CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):230; ITHMAX 1(A) / F1(HZ):40 /50; I LN (A):36; UK(%):2; LN(MH):0,35; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; EN 61558-2-20 >CHOKE<

4EM4912-8CB

1PH-COMMUTATING REACTOR 45A FOR 230V 50HZ VOLTAGE DROP 4.4V

4EM4912-8CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):230; ITHMAX 1(A) / F1(HZ):45 /50; I LN (A):40,5; UK(%):2; LN(MH):0,311; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW CONNECTION; EN 61558-2-20 >CHOKE<

4EM4913-1CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):400; ITHMAX 1(A) / F1(HZ):16 /50; I LN (A):14,4; UK(%):4; LN(MH):4,84; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >UL/CSA-RECOGNIZED< >CHOKE<

4EM4914-5CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):460; ITHMAX 1(A) / F1(HZ):8 /60; I LN (A):7,2; UK(%):4; LN(MH):6,1; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >CHOKE<

4EM4914-6CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):460; ITHMAX 1(A) / F1(HZ):11,2 /60; I LN (A):10,1; UK(%):4; LN(MH):4,35; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >CHOKE<

4EM4914-7CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):460; ITHMAX 1(A) / F1(HZ):10 /60; I LN (A):9; UK(%):4; LN(MH):4,9; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >CHOKE<

4EM4914-8CB00

SMOOTHING CHOKE; PHASES:1; U ISO(V):600; I(DC)(A):1,75; EN(WS):0,383; PV(W):12,9; LN(MH):250; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >CHOKE<

4EM4915-0CB00

COMMUTATING CHOKE FOR CONVERTER; PHASES:1; UN1(V):480; ITHMAX 1(A) / F1(HZ):20 /50; I LN (A):18; UK(%):2; LN(MH):1,528; TA/ISOKL:40 /B; IP00; TYPE OF TERMINALS:SCREW/TAB CONNECTION; EN 61558-2-20 >AUTOTRANSFORMER<