1PS1113-0CD..-3BB2
LOW-VOLTG. SQUIRREL-CAGE MOTOR LOHER TYPE: AMGK-112MB-04 LINE FEED CHEMSTAR, SPECIAL ROTOR EX N A II, VIK IP56, IC411, SIZE 112, IE2 4 POLE 4 KW AT 50HZ
1PS1113-0CD..-3CA0
LOW-VOLTG. SQUIRREL-CAGE MOTOR LOHER TYPE: AMGK-112MB-06 LINE FEED CHEMSTAR, STANDARD ROTOR EX N A II, VIK IP56, IC411, SIZE 112 6 POLE 2,2 KW AT 50HZ
1PS1113-0CD..-3CA2
LOW-VOLTG. SQUIRREL-CAGE MOTOR LOHER TYPE: AMGK-112MB-06 LINE FEED CHEMSTAR, STANDARD ROTOR EX N A II, VIK IP56, IC411, SIZE 112, IE2 6 POLE 2,2 KW AT 50HZ
1PS1113-0ND..-3NA0
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MB-42 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 4/2-POLIG 1,1/4,1 KW BEI 50HZ
1PS1113-0ND..-3NA3
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MS-42 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 4/2-POLIG 1,1/4,1 KW BEI 50HZ
1PS1113-0ND..-3PA0
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MB-64 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 6/4-POLIG 0,9/3 KW BEI 50HZ
1PS1113-0ND..-3PA3
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MS-64 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 6/4-POLIG 0,9/3 KW BEI 50HZ
1PS1113-0ND..-3QA0
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MB-84 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 8/4-POLIG 0,9/3,7 KW BEI 50HZ
1PS1113-0ND..-3QA3
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MS-84 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 8/4-POLIG 0,9/3,7 KW BEI 50HZ
1PS1113-0ND..-3RA0
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MB-86 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 8/6-POLIG 0,8/1,9 KW BEI 50HZ
1PS1113-0ND..-3RA3
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MS-86 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 8/6-POLIG 0,8/1,9 KW BEI 50HZ
1PS1113-0ND..-3SA0
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MB-33 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 8/6/4-POL. 0,6/0,85/2,4 KW BEI 50HZ
1PS1113-0ND..-3SA3
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: AVGK-112MS-33 NETZBETRIEB NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112 8/6/4-POL. 0,6/0,85/2,4 KW BEI 50HZ
1PS1113-1BD..-3AA0
LOW-VOLTG. SQUIRREL-CAGE MOTOR LOHER TYPE: ANGK-112MB-02 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR EX NA II T3 IP55, IC411, SIZE 112 2 POLES 4 KW AT 50HZ
1PS1113-1BD..-3AA2
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: ANGK-112MB-02 UMRICHTERBETRIEB, NORMALISOL. NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112, IE2 2-POLIG 4 KW BEI 50HZ
1PS1113-1BD..-3AA3
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: ANGK-112MS-02 UMRICHTERBETRIEB, NORMALISOL. NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112, IE2 2-POLIG 4 KW BEI 50HZ
1PS1113-1BD..-3AA4
Niederspannungsmotor, 3PH AC Plattform Loher Chemstar Typ: ANGK-112MS-02 VSD, Normalisolation II 3G EX NA IIC T3 GC IP55, IC411, Baugr. 112, IE2 2-polig 4kW bei 50Hz, DOL
1PS1113-1BD..-3AH3
LV-MOTOR, KL, CHEMSTAR LOHER TYPE: ANGK-112MT-02 UMRICHTERBETRIEB, NORMALISOL. NORMALLAEUFER II 3G EX NA IIC T3 GC IP55, IC411, BG 112, IE3 2-POLIG 4 KW BEI 50HZ
1PS1113-1BD..-3AH4
LV-MOTOR, 3PH AC Plattform LOHER CHEMSTAR TYPE: ANGK-112MT-02 VSD, Normalisolation II 3G EX NA IIC T3 GC IP55, IC411, Baugr. 112, IE3 2-polig 4 kW BEI 50HZ, DOL
1PS1113-1BD..-3BA0
LOW-VOLTG. SQUIRREL-CAGE MOTOR LOHER TYPE: ANGK-112MB-04 CONVERTER FEED, STANDARD INSUL. STANDARD ROTOR EX NA II T3 IP55, IC411, SIZE 112 4 POLES 4 KW AT 50HZ
Wir liefern weltweit und zu jeder Zeit incl. Zollabfertigung.